Sekonic DIGI LITE F L-328 Istruzioni per gli Interventi

Navigare online o scaricare Istruzioni per gli Interventi per Misurazione, test & controllo Sekonic DIGI LITE F L-328. Sekonic DIGI LITE F L-328 Operating instructions [en] Manuale Utente

  • Scaricare
  • Aggiungi ai miei manuali
  • Stampa
  • Pagina
    / 16
  • Indice
  • SEGNALIBRI
  • Valutato. / 5. Basato su recensioni clienti
Vedere la pagina 0
SEKONIC
DIGI LITE F L-328
Operating Instructions
Vedere la pagina 0
1 2 3 4 5 6 ... 15 16

Sommario

Pagina 1 - SEKONIC

SEKONIC DIGI LITE F L-328 Operating Instructions

Pagina 2 - Parts Designations

Post-Measurement Calculation 1. By changing ISO sensitivity the measured F-stop value will automatically be altered to the appropriate one corres

Pagina 3 - Liquid Crystal Display

Contrast Metering for Lighting Balance When calculating a desired lighting balance, the meter can be used to measure thebrightness of main and fill-in

Pagina 4 - Preparin

Illuminance (LUX) Measurement The meter can be used as a LUX meter when used with the Lumidisc in the ambient lightmeasuring mode.1. Mount the Lumidi

Pagina 5

Accessories Lumisphere • Use the Lumisphere when you wish to measure incident light forportraits and three-dimensional subjects. In case of incident l

Pagina 6

Specification Measuring system • Incident and reflected light measurement Flash light for wireless and wired, and ambient light measurements Meas

Pagina 7

Care of Your Meter DIGI LITE F meter is a high-precision instrument containing delicate electronic parts and components, and you are recommended to ha

Pagina 8 - Ambient Light Measurement

SEKONIC CORPORATION 7-24-14, OIZUMI-GAKUEN-CHO, NERIMA-KU, TOKYO 178-8686, JAPAN TEL:(03)3978-2335 FAX: (03)3978-5229 T19134OB-A

Pagina 9

Parts Designations Lumisphere Swivel Head (270° rotatable) Liquid crystal display Measuring switch Power switch UP/DOWN key Mode selection switch ISO

Pagina 10 - Post-Measurement Calculation

Liquid Crystal Display (1) (2) (3) - By pressing F/W key, the indicated symbol will be converted from F to EV, and vice versa. When t

Pagina 11

Preparing the Meter for Operation 1. Inserting the battery The meter uses a single AA size pen-light battery (1.5h. Open the battery chamber cover by

Pagina 12

44. Setting ISO sensitivity Press either side of UP/DOWN key while holding ISO key depressed so that the ISO number of your film is displayed.

Pagina 13 - Accessories

2. Set the film speed (ISO) and shutter speed (T) as shown in the paragraph for "Preparing the Meter for Operation". 3. Press the measurin

Pagina 14 - Specification

Measurement using Flash Unit with Synchro Cord It is recommended that the meter is used in the wired measurement mode when the flash light is measured

Pagina 15 - Care of Your Meter

Ambient Light Measurement Measuring ambient light, whether it is daylight or standard electric light, is a fairlysimple matter using either incident o

Pagina 16 - SEKONIC CORPORATION

The procedures for taking measurements when using a movie camera are the same as for taking ambient light measurements. Keep depressing the UP side of

Commenti su questo manuale

Nessun commento