Sekonic L-358 Manuale Utente

Navigare online o scaricare Manuale Utente per Strumenti di misura Sekonic L-358. Sekonic L-358 User Manual Manuale Utente

  • Scaricare
  • Aggiungi ai miei manuali
  • Stampa

Sommario

Pagina 1 - Flash Master L-358

Flash Master L-358Operating Manual

Pagina 2 - Blank page

-6-8. Mesurement Lock and Measurement Lock Off 1. Hold down the Mode set button !0 and ISO1 button !1and "LOC" will appear to indicate that

Pagina 3

-7-4. Basic Operation1. Setting measuring mode1. Hold down the Mode set button !0 and turn the Jog wheelt to select the desired mode. The mode switch

Pagina 4 - Table of Contents

-8-4. Basic Operation2. Setting DIP Switches1. Switches for setting modes that are used infrequently are housed in the Battery compartment ofthe mete

Pagina 5 - 1. Parts Designation

-9-3. When set for incident light1. Incident light measurements can be performed with the lumisphere fully extended or in theretracted position. You c

Pagina 6

-10-4. Basic Operation4. When set for reflected light• This method measures the brightness (luminance) of the light reflected from the subject. It is

Pagina 7

-11-5. Measurement1. Measuring ambient lightIn this measurement mode, we have the choice of shutter priority mode, aperture priority mode andEV mode.

Pagina 8 - FLASHMASTER

-12-1-2 Aperture Priority mode1. Hold down the Mode set button !0 and turn the Jog wheelt to select aperture priority mode .2. Turn the Jog wheel to

Pagina 9

-13-1-3 EV modeOpen the Battery compartment cover !6 and slide the EV DIP switch (see page 8) to the ONposition.1. Hold down the Mode set button !0 an

Pagina 10 - 3. Before Using

-14-1-4 Cinematography1. Hold down the Mode set button !0 and turn the Jog wheelt to select ambient light shutter speed priority mode.2. Turn the Jog

Pagina 11 - 4. Basic Operation

-15-2. Measuring flash lightThis method of measurement can be done in the following modes; with cord, without cord, multipleflash with cord, multiple

Pagina 12

Blank page

Pagina 13

-16-2-2 Auto-reset cordless flash modeMeasurements are made by the meter receiving the light from the flash. This measurementmode is used when the Syn

Pagina 14

-17-3. When the Measuring button !5 is pressed, themode mark will blink and the meter is ready tomeasure. The ready to measure mode will continuefor a

Pagina 15 - 5. Measurement

-18-2-3 Cord multiple flash (cumulative) modeThese measurements are used when the light generated by the flash is inadequate for properexposure. The r

Pagina 16

-19-2-4 Cordless flash (cumulative) modeThese measurements are used when the light generated by the flash is inadequate for properexposure. The repeat

Pagina 17

-20-3. When the light from the flash is received, the measured value (f stop) is displayed. Eachtime this is repeated, the accumulated value for the a

Pagina 18

-21-6. Advanced Functions1. Memory functionThis meter can store up to nine measured values in memory. This feature can be used in the follow-ing mode

Pagina 19

-22-2. Averaging functionThis function displays the average of two to nine of the values in memory.1. Press the Measuring button ! 5 and take ameasur

Pagina 20

-23-3. Brightness difference functionThis function is useful for evaluating studio lighting and checking the evenness of the lighting set-upacross the

Pagina 21

-24-5. The Brightness Difference mode can be canceled by pressing the Ave/Δ EV button r.Reference:・To determine exposure after adjusting lights, turn

Pagina 22

-25-6. Advanced Functions4. How to use the L358 as an incident illuminance (LUX or FC) meter1. Turn the Lumisphere Retracting ring q to lower it toth

Pagina 23

Congratulations on your purchase of aSekonic Flash Master L-358 Light Meter.This meter provides a wide range of functions that correspond with mostman

Pagina 24

-26-6. Advanced FunctionsNOTE:• Make compensation after a sufficient number of test in actual photographic conditions,to suit your needs.• Compensati

Pagina 25 - 6. Advanced Functions

-27-6. Advanced Functions6. Flash analyzing measurement functionWhen measuring flash light, the shutter speed and F stop value (value combining ambie

Pagina 26 - AVE./∆EV

-28-6. Advanced FunctionsMODE7. Wireless flash radio triggering functionWith the radio transmitter module plugged into the meters radio compartment a

Pagina 27

-29-6. Advanced FunctionsCAUTION• When using quad channels 17-32, it is not possible to terminate this mode unless a sub-channel has been set (a, b,

Pagina 28

-30-6. Advanced FunctionsReference:• Refer to the receiver instruction manual for the receiver operating method.• Maximum controllable distance of th

Pagina 29

-31-Mini Light Receptor (Sold separately)• Incident light receiving unit with a compact 12mm diameterlight receiving surface.• For measuring narrow ar

Pagina 30 - ISO 1 ISO 2

-32-7. AccessoriesNP Finder; Non-parallax spot viewfinder attachment with ordinary waterproof structure(Sold separately)• There are three types of NP

Pagina 31

-33- · Type : Digital light meter for ambient and flash light · Light receiving method : Incident light and reflected light · Light ReceptorsIncident

Pagina 32

-34- · Other features :All-weather feature : JIS standard water resistance class 4, splash-proof typeMemory function : 9 readingsMemory clear・recall f

Pagina 33

-35-• Please keep in a location where an infant cannot reach and accidentally get thestrap wrapped around his neck. There is danger of strangulation.•

Pagina 34

Table of Contents1. Parts Designation ...

Pagina 35 - 7. Accessories

-36-NOTE:• Although this meter has an All-weather design for everyday use (JIS standard waterresistance class 4), do not place it in water or use it u

Pagina 36

-37-FCC & IC compliance information:Warning: Changes or modifications to this unit not expressly approved by the party responsible forcompliance c

Pagina 42

Blank page

Pagina 43

7-24-14, OIZUMI-GAKUEN-CHO, NERIMA-KU, TOKYO 178-8686 JAPANTEL:+81(0)3-3978-2335 FAX:+81(0)3-3978-5229http://www.sekonic.co.jpJC1097582

Pagina 44

Radio Transmitter RT-32CTLOperating Manual Thank you for purchasing this product.Please read the instruction manual thoroughly to assure its safe and

Pagina 45

POWERFLASH MASTERL-358MEMORYMODEISO 2ISO 1AVE./∆EV-1-1. Parts Designation@0 Synchro Terminal Cap!6 Battery Compartment Cover!5 Measuring button!7 Ba

Pagina 46

4. How to attach the operating label to the light meter.(For FCC & IC versions)Please stick "Label B" on area of current &quo

Pagina 47

1 * *2 * *3 * *4 *-5 - -6 - -7- -8- -9 - -- -- -- -- -- -- -- -JQ7D97540  RADIO TRANSMITTER RT-32CTL1. Radio Channel Selector Sheet - Channel 1

Pagina 48 - JC1097582

 RADIO TRANSMITTER RT-32CTL 2. Radio Channel Selector Sheet  - Channel 17 to 32 -This channel assignment is applied to L-358 onlyCH17 to 32 - - - Sele

Pagina 49 - Operating Manual

-2-2. Explanation of the Liquid Crystal DisplayAuto Electro-Luminescent Display (EL)In low light (EV 6 or less), a green backlight will automatically

Pagina 50 - FAX. ++ 81-3-3978-5229

q Measuring Mode IconsAmbient (see page 11)Auto-Reset Cordless Flash (see page 17)Cord Flash (see page 15)Wireless flash radio triggering mode (see pa

Pagina 51 - RADIO TRANSMITTER RT-32CTL

-4-Reference:・ We recommend you always have a spare battery on hand.・ If the liquid crystal display extinguishes immediately after the display appears

Pagina 52

-5-3. Before Using4. Replacing battery during measurement or when using the memory function1. Always turn the power OFF before replacing batteries. I

Commenti su questo manuale

Nessun commento